The 2-Minute Rule for Dp50rb

Guidance 4D probe; figure out the probe via the ID code; swap the 4D drive sign by means of the  electrical relay to make the 4D probe function normally. four.2.2 Major board The principle board could possibly be divided into two elements: entrance-finish of the main board and back again-end of the most crucial board.

one.2.2 Warning Labels Warning Labels Which means Remember to thoroughly look at this manual in advance of use device. The subsequent labels certainly are a. Usually do not area the device on the sloped surface area. Usually the out there once the program unit may well slide, causing particular harm or even the gadget operates Together with the mobile malfunction.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat element login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Any time you end the scanning as well as the image capture, you need to electrical power from the program and disconnect the system within the AC electricity source, then pull out AC electricity cables. Web page 109: Battery Connecting Board

By continuing your take a look at on our Web page, you might be consenting to our usage of cookies. On the other hand, you may modify your cookie configurations at any time.  Cookie choice Accept and Progress

Reduce off cable ties connecting the leading unit over the Exhibit by diagonal chopping pliers, and after that pull out the corresponding cable plugs.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

S. have to provide the Section with an email deal with if they have got a person. The e-mails furnished might be useful for Formal conversation While using the licensee. Nonetheless email addresses are community document. If you don't want to supply a private tackle, make sure you offer the Department with the e mail address that may be created accessible to the general public. To determine If you're a licensee under Chapter 455, File.S., make sure you Click this link . Item Approval Accepts:

This handbook may well referring to info shielded by copyright or patents and would not Express any license under the patent legal rights or copyright of Mindray, or of Other individuals. Website page nine: Assertion

The chapter materials the strategy to validate primary purpose and functionality of item. This can be only utilized for reference, not preventive execution. Operate examining Dp50rb and testing of this portion shall be performed by Mindray company engineers plus the consumer together. Web site 66: Typical Exam

Notice: To the keep an eye on, the brightness adjustment arrives ahead of contrast. Soon after readjusting the keep track of’s contrast and brightness, alter all preset and peripheral options.

Take note: Before inserting the connector into your probe port, inspect the connector pin. In case the pin is bent, tend not to use the probe until it has been inspected / fixed / changed. Putting in Peripherals To the models with the supported peripherals, make sure you check with “two.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

General performance Exam five.five.1 Test Process Resolution Detection depth Geometric Position Precision Blackout spot test History the Test photographs five.5.two Examination Articles The image applied here is just for reference, stay with the image outcome in the real Notice: situation. Necessities: Show: established the distinction and brightness in the clinical application price (or maybe the default position) Procedure surroundings: darkish place, simulating the medical software setting. Page seventy six In condition that the transverse resolution tests targets are horizontally exhibited, record the minimum length of two targets that may be Obviously acknowledged. Repeat the operation higher than for the transverse resolution tests targets at other depths. As demonstrated in determine down below. Axial resolution ... Web site seventy seven When utilizing the convex probe, maintain the transverse resolution testing targets to NOTE: be shown near the midline. When employing a linear probe with steer perform, don't activate the steer perform when carry out the transverse resolution check. Zoom in the location the place the targets located if required. The diameter with the concentrate on stage at a particular depth is equal on the transverse resolution within the depth. Page 78 5.

A sensible new shape, Increased mobility and easy operation make DP-fifty well matched for all clinical configurations.

five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Exam Phase: Do adjustments as just how in screening the most depth. File the space by 20mm Each individual segment within the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest error (to 20mm), compute the accuracy using the system below The measurement caliper should be positioned with the higher fringe of the goal, Take note:... Webpage seventy nine Transverse geometric positioning precision  Check Move: Cover the scan surface area of your phantom with h2o or couple gel, gently Speak to the probe Using the scan surface Modify the depth, producing the transverse targets to generally be displayed within the picture. Modify the focus stage for being posited beside the transverse targets (the normal will not be apparent) Regulate parameters like attain, TGC, earning each transverse targets to be Plainly displayed. Page 80 five.5.two.four Blackout Spot Examination Stage: Cover the scan area on the phantom with water or few gel, Carefully Get hold of the probe Along with the scan surface Change the depth in a decrease benefit, and set the main focus at the closest place to the scan surface area. Lessen the worth of parameters like AP, Obtain till the qualifications sound just can be witnessed. Web site 81: Computer software Up grade And Routine maintenance